Product Description
Moisture in compressed air systems is a common hazard leading to equipment failure and production losses. As high-temperature compressed air cools within the piping, water vapor condenses into liquid water; this can corrode pipelines, damage pneumatic components, compromise product quality, and even cause unplanned production line downtime.
Installed downstream of the compressor, the Sollant water-cooled aftercooler facilitates efficient heat exchange between high-temperature compressed air and circulating cooling water. It rapidly condenses water vapor into liquid water-which is automatically discharged from the system-thereby minimizing moisture entry into downstream piping and equipment at the source. By effectively protecting dryers, filters, and point-of-use equipment, it helps reduce maintenance frequency and spare part replacement costs while ensuring continuous, stable production. It serves as an indispensable pre-drying stage in compressed air systems.
Product Features
Precise Temperature Control: Ensures discharge air temperature remains stable within an ideal range, aligning perfectly with the inlet requirements of various dryers.
Strong Operational Adaptability: Accommodates a wide range of cooling water temperatures and pressures, offering flexibility for diverse site conditions.
Ultra-Low Pressure Drop: Features an optimized flow path design that minimizes pressure loss, avoiding additional energy consumption by the compressor.
Rugged Durability: Constructed with rust- and corrosion-resistant materials and reliable sealing technology to ensure stable, long-term operation.
Easy Installation and Maintenance: Compact structure with quick flange connections; removable end caps for convenient tube bundle cleaning; integrated automatic drainage to reduce daily maintenance workload.
Technical Specifications of the Water-Cooled After Cooler

Comparison of Air-Cooled and Water-Cooled After Coolers
|
Comparison Criteria |
Air-cooled after cooler |
Water-cooled after cooler |
|
Cooling medium |
Ambient air |
Cooling water (industrial circulating water or tap water) |
|
Cooling Capacity Stability |
Fluctuates with changes in ambient temperature; cooling performance drops somewhat in summer and improves in winter. |
Cooling water temperature remains relatively stable, outlet air temperature shows minimal fluctuation, and operational consistency is high throughout the year. |
|
Installation Requirements |
Easy to install; simply place in a well-ventilated area; no water piping required. |
Requires installation of inlet and outlet water piping and a matching cooling tower or water reservoir; involves significant installation work. |
|
Outlet temperature stability |
Significantly affected by ambient temperature; outlet temperature is higher in summer and lower in winter |
Cooling water temperature is relatively stable; outlet temperature fluctuates minimally throughout the year |
|
Routine Maintenance |
Regularly clean dust from the surface of the cooling fins to ensure unobstructed airflow. |
Periodically descale and clean heat exchange tubes, monitor water quality, and dose with water treatment chemicals. |
|
Operational energy consumption |
Primarily electricity consumption of the fans |
Primarily electricity consumption of the circulating water pumps |
|
Applicable Operating Conditions |
Water-scarce regions; applications requiring low to medium flow rates and compact installation space |
Applications with circulating water availability, medium to high flow rates, and strict requirements for outlet temperature stability |
Hot Tags: water-cooled after cooler, China water-cooled after cooler manufacturers, suppliers, factory, air cooled aftercooler for air compressor, air separator for air compressor, compressed air aftercooler water cooled, compressed air oil removal, Precision Filtration Systems, Waste Oil Collector